SINOTECH+ Everolimus-Eluting Coronary Stent

The SINOTECH+ cobalt-chromium coronary stent system with an everolimus drug-eluting coating, indicated for PTCA to permanently dilate stenotic native coronary arteries and improve myocardial perfusion.

SINOTECH+ Everolimus-Eluting Coronary StentSINOTECH+

Overview

The SINOTECH+ everolimus-eluting stent is a cylindrical cobalt-chromium (Co-Cr) mesh framework with a waved open-cell design and an everolimus drug coating. Delivered folded on a balloon catheter, it is expanded at the stenosis to restore blood flow, while the drug coating treats the artery wall and helps prevent excessive tissue growth (restenosis). It should be used only by physicians experienced in PTCA and stent implantation.

Key features

  • Cobalt-chromium (Co-Cr) platform with 70 μm wall thickness
  • Everolimus drug coating to lower the risk of restenosis
  • Waved open-cell structure for uniform expansion and vessel adaptation
  • Delivered pre-mounted on a balloon catheter
  • Six diameters (2.25–4.00 mm) and eight lengths (8–42 mm)

Clinical applications

  • Percutaneous Transluminal Coronary Angioplasty (PTCA)
  • Permanent dilation of stenotic native coronary arteries
  • Improvement of myocardial perfusion

Intended use

Cardiac surgery. The SINOTECH+ everolimus-eluting coronary stent system is indicated for Percutaneous Transluminal Coronary Angioplasty (PTCA) — the permanent dilation of the stenotic portion of a native coronary artery by placement of a coronary stent, to improve myocardial perfusion. For use only by physicians with significant experience in PTCA and stent-implantation procedures.

How it's used

Coronary stents are cylindrical, drug-coated mesh frameworks inserted into narrowed sections of an artery to expand them. Cholesterol plaque can accumulate and reduce — or completely block — blood flow, starving the heart muscle of oxygen. The stent is delivered folded over a balloon catheter to the lesion and expanded, widening the vessel and restoring flow; the antiproliferative drug coating then treats the artery wall and helps prevent excessive tissue regrowth (restenosis).

Specifications

Material
Cobalt-chromium (Co-Cr)
Drug coating
Everolimus (drug-eluting)
Wall thickness
70 μm
Design
Waved open cell
Diameters
2.25 / 2.50 / 2.75 / 3.00 / 3.50 / 4.00 mm
Lengths
8 / 12 / 18 / 24 / 28 / 34 / 38 / 42 mm
Guidewire
0.014"

Manufactured by TIBTEXNIKA LLC (Uzbekistan). Distributed in Pakistan by SURGIPRO as the authorized representative & importer. Specifications are indicative — always refer to the manufacturer's Instructions for Use (IFU). For use by qualified healthcare professionals only.

Diagram

SINOTECH+ delivery system — balloon-catheter dimensions with maximum guide-wire (0.36 mm / 0.014") and minimum guiding-catheter inner diameter (1.42 mm / 0.056").
SINOTECH+ delivery system — balloon-catheter dimensions with maximum guide-wire (0.36 mm / 0.014") and minimum guiding-catheter inner diameter (1.42 mm / 0.056").
A drug-eluting stent restoring blood flow in a plaque-narrowed artery.
A drug-eluting stent restoring blood flow in a plaque-narrowed artery.

Click a diagram to open it full size.

Technical parameters

Material
Cobalt-chromium alloy (Co-Cr) — high strength, corrosion resistance and biocompatibility
Wall thickness
70 µm — among the thinnest available, improving flexibility and minimising vascular trauma
Design
Waved open-cell — uniform expansion and conformability to vessel bends
Drug coating
Everolimus (drug-eluting) — limits smooth-muscle hyperplasia and restenosis
Diameters
2.25 · 2.50 · 2.75 · 3.00 · 3.50 · 4.00 mm
Lengths
8 · 12 · 18 · 24 · 28 · 34 · 38 · 42 mm
Delivery
Rapid-exchange catheter with two radiopaque markers

Sizes & ordering

Available sizes & order codes

Stent diameter (mm)Stent length (mm)
812182428343842
2.25DES-225-08DES-225-12DES-225-18DES-225-24DES-225-28DES-225-34DES-225-38DES-225-42
2.50DES-250-08DES-250-12DES-250-18DES-250-24DES-250-28DES-250-34DES-250-38DES-250-42
2.75DES-275-08DES-275-12DES-275-18DES-275-24DES-275-28DES-275-34DES-275-38DES-275-42
3.00DES-300-08DES-300-12DES-300-18DES-300-24DES-300-28DES-300-34DES-300-38DES-300-42
3.50DES-350-08DES-350-12DES-350-18DES-350-24DES-350-28DES-350-34DES-350-38DES-350-42
4.00DES-400-08DES-400-12DES-400-18DES-400-24DES-400-28DES-400-34DES-400-38DES-400-42

Pre-mounted on a balloon delivery catheter. Order-code format: DES-[diameter]-[length].

Exact dimensional figures, full pressure-compliance charts and order codes are confirmed against the manufacturer's current Instructions for Use (IFU) and catalogue. Request the full datasheet.

Quality & certification

Manufactured under GMP technology by TIBTEXNIKA LLC with internationally certified quality-management systems.

  • ISO 13485:2016
  • ISO 9001:2015
  • Production Licence
  • CE Certificate
Manufacturer
TIBTEXNIKA LLC, Uzbekistan
Category
Coronary Stents
Product family
SINOTECH+
Quality system
GMP · ISO 13485:2016
Regulatory
DRAP — Medical Devices Rules, 2017
Documentation
IFU, datasheet, Free Sale & registration — on request
Intended user
Qualified healthcare professionals only

Product registration certificate

Click a certificate to open it full size.

All devices manufactured by TIBTEXNIKA LLC, Uzbekistan.