SINOTECH+ Sirolimus-Eluting Coronary Stent
The SINOTECH+ cobalt-chromium coronary stent system with a sirolimus drug-eluting coating, indicated for PTCA to permanently dilate stenotic native coronary arteries and improve myocardial perfusion.
SINOTECH+Overview
The SINOTECH+ sirolimus-eluting stent pairs a thin-walled cobalt-chromium (Co-Cr) scaffold with a waved open-cell geometry and a sirolimus coating (1.4 µg/mm²). After delivery and balloon expansion at the lesion, the drug coating limits excessive tissue growth (hyperplasia) to help prevent in-stent restenosis. For use only by physicians experienced in PTCA and stent implantation.
Key features
- Cobalt-chromium (Co-Cr) platform with 70 μm wall thickness
- Sirolimus coating, 1.4 µg/mm² drug content
- Waved open-cell structure for uniform expansion and vessel adaptation
- Delivered pre-mounted on a balloon catheter
- Six diameters (2.25–4.00 mm) and eight lengths (8–42 mm)
Clinical applications
- Percutaneous Transluminal Coronary Angioplasty (PTCA)
- Permanent dilation of stenotic native coronary arteries
- Reduction of in-stent restenosis risk
Intended use
Cardiac surgery. The SINOTECH+ sirolimus-eluting coronary stent system is indicated for Percutaneous Transluminal Coronary Angioplasty (PTCA) — the permanent dilation of the stenotic portion of a native coronary artery by placement of a coronary stent, to improve myocardial perfusion. For use only by physicians with significant experience in PTCA and stent-implantation procedures.
How it's used
Coronary stents are cylindrical, drug-coated mesh frameworks inserted into narrowed sections of an artery to expand them. Cholesterol plaque can accumulate and reduce — or completely block — blood flow, starving the heart muscle of oxygen. The stent is delivered folded over a balloon catheter to the lesion and expanded, widening the vessel and restoring flow; the antiproliferative drug coating then treats the artery wall and helps prevent excessive tissue regrowth (restenosis).
Specifications
- Material
- Cobalt-chromium (Co-Cr)
- Drug coating
- Sirolimus (drug-eluting)
- Drug content
- 1.4 µg/mm²
- Wall thickness
- 70 μm
- Design
- Waved open cell
- Diameters
- 2.25 / 2.50 / 2.75 / 3.00 / 3.50 / 4.00 mm
- Lengths
- 8 / 12 / 18 / 24 / 28 / 34 / 38 / 42 mm
Manufactured by TIBTEXNIKA LLC (Uzbekistan). Distributed in Pakistan by SURGIPRO as the authorized representative & importer. Specifications are indicative — always refer to the manufacturer's Instructions for Use (IFU). For use by qualified healthcare professionals only.
Technical parameters
- Material
- Cobalt-chromium alloy (Co-Cr) — high strength, corrosion resistance and biocompatibility
- Wall thickness
- 70 µm — among the thinnest available, improving flexibility and minimising vascular trauma
- Design
- Waved open-cell — uniform expansion and conformability to vessel bends
- Drug coating
- Sirolimus (drug-eluting) — 1.4 µg/mm² — limits smooth-muscle hyperplasia and restenosis
- Diameters
- 2.25 · 2.50 · 2.75 · 3.00 · 3.50 · 4.00 mm
- Lengths
- 8 · 12 · 18 · 24 · 28 · 34 · 38 · 42 mm
- Delivery
- Rapid-exchange catheter with two radiopaque markers
Sizes & ordering
Available sizes & order codes
| Stent diameter (mm) | Stent length (mm) | |||||||
|---|---|---|---|---|---|---|---|---|
| 8 | 12 | 18 | 24 | 28 | 34 | 38 | 42 | |
| 2.25 | DES-225-08 | DES-225-12 | DES-225-18 | DES-225-24 | DES-225-28 | DES-225-34 | DES-225-38 | DES-225-42 |
| 2.50 | DES-250-08 | DES-250-12 | DES-250-18 | DES-250-24 | DES-250-28 | DES-250-34 | DES-250-38 | DES-250-42 |
| 2.75 | DES-275-08 | DES-275-12 | DES-275-18 | DES-275-24 | DES-275-28 | DES-275-34 | DES-275-38 | DES-275-42 |
| 3.00 | DES-300-08 | DES-300-12 | DES-300-18 | DES-300-24 | DES-300-28 | DES-300-34 | DES-300-38 | DES-300-42 |
| 3.50 | DES-350-08 | DES-350-12 | DES-350-18 | DES-350-24 | DES-350-28 | DES-350-34 | DES-350-38 | DES-350-42 |
| 4.00 | DES-400-08 | DES-400-12 | DES-400-18 | DES-400-24 | DES-400-28 | DES-400-34 | DES-400-38 | DES-400-42 |
Pre-mounted on a balloon delivery catheter. Order-code format: DES-[diameter]-[length].
Exact dimensional figures, full pressure-compliance charts and order codes are confirmed against the manufacturer's current Instructions for Use (IFU) and catalogue. Request the full datasheet.
Quality & certification
Manufactured under GMP technology by TIBTEXNIKA LLC with internationally certified quality-management systems.
- ISO 13485:2016
- ISO 9001:2015
- Production Licence
- CE Certificate
- Manufacturer
- TIBTEXNIKA LLC, Uzbekistan
- Category
- Coronary Stents
- Product family
- SINOTECH+
- Quality system
- GMP · ISO 13485:2016
- Regulatory
- DRAP — Medical Devices Rules, 2017
- Documentation
- IFU, datasheet, Free Sale & registration — on request
- Intended user
- Qualified healthcare professionals only
Product registration certificate
Click a certificate to open it full size.