SINOTECH+ Sirolimus-Eluting Coronary Stent

The SINOTECH+ cobalt-chromium coronary stent system with a sirolimus drug-eluting coating, indicated for PTCA to permanently dilate stenotic native coronary arteries and improve myocardial perfusion.

SINOTECH+ Sirolimus-Eluting Coronary StentSINOTECH+

Overview

The SINOTECH+ sirolimus-eluting stent pairs a thin-walled cobalt-chromium (Co-Cr) scaffold with a waved open-cell geometry and a sirolimus coating (1.4 µg/mm²). After delivery and balloon expansion at the lesion, the drug coating limits excessive tissue growth (hyperplasia) to help prevent in-stent restenosis. For use only by physicians experienced in PTCA and stent implantation.

Key features

  • Cobalt-chromium (Co-Cr) platform with 70 μm wall thickness
  • Sirolimus coating, 1.4 µg/mm² drug content
  • Waved open-cell structure for uniform expansion and vessel adaptation
  • Delivered pre-mounted on a balloon catheter
  • Six diameters (2.25–4.00 mm) and eight lengths (8–42 mm)

Clinical applications

  • Percutaneous Transluminal Coronary Angioplasty (PTCA)
  • Permanent dilation of stenotic native coronary arteries
  • Reduction of in-stent restenosis risk

Intended use

Cardiac surgery. The SINOTECH+ sirolimus-eluting coronary stent system is indicated for Percutaneous Transluminal Coronary Angioplasty (PTCA) — the permanent dilation of the stenotic portion of a native coronary artery by placement of a coronary stent, to improve myocardial perfusion. For use only by physicians with significant experience in PTCA and stent-implantation procedures.

How it's used

Coronary stents are cylindrical, drug-coated mesh frameworks inserted into narrowed sections of an artery to expand them. Cholesterol plaque can accumulate and reduce — or completely block — blood flow, starving the heart muscle of oxygen. The stent is delivered folded over a balloon catheter to the lesion and expanded, widening the vessel and restoring flow; the antiproliferative drug coating then treats the artery wall and helps prevent excessive tissue regrowth (restenosis).

Specifications

Material
Cobalt-chromium (Co-Cr)
Drug coating
Sirolimus (drug-eluting)
Drug content
1.4 µg/mm²
Wall thickness
70 μm
Design
Waved open cell
Diameters
2.25 / 2.50 / 2.75 / 3.00 / 3.50 / 4.00 mm
Lengths
8 / 12 / 18 / 24 / 28 / 34 / 38 / 42 mm

Manufactured by TIBTEXNIKA LLC (Uzbekistan). Distributed in Pakistan by SURGIPRO as the authorized representative & importer. Specifications are indicative — always refer to the manufacturer's Instructions for Use (IFU). For use by qualified healthcare professionals only.

Diagram

SINOTECH+ delivery system — balloon-catheter dimensions with maximum guide-wire (0.36 mm / 0.014") and minimum guiding-catheter inner diameter (1.42 mm / 0.056").
SINOTECH+ delivery system — balloon-catheter dimensions with maximum guide-wire (0.36 mm / 0.014") and minimum guiding-catheter inner diameter (1.42 mm / 0.056").
A drug-eluting stent restoring blood flow in a plaque-narrowed artery.
A drug-eluting stent restoring blood flow in a plaque-narrowed artery.

Click a diagram to open it full size.

Technical parameters

Material
Cobalt-chromium alloy (Co-Cr) — high strength, corrosion resistance and biocompatibility
Wall thickness
70 µm — among the thinnest available, improving flexibility and minimising vascular trauma
Design
Waved open-cell — uniform expansion and conformability to vessel bends
Drug coating
Sirolimus (drug-eluting) — 1.4 µg/mm² — limits smooth-muscle hyperplasia and restenosis
Diameters
2.25 · 2.50 · 2.75 · 3.00 · 3.50 · 4.00 mm
Lengths
8 · 12 · 18 · 24 · 28 · 34 · 38 · 42 mm
Delivery
Rapid-exchange catheter with two radiopaque markers

Sizes & ordering

Available sizes & order codes

Stent diameter (mm)Stent length (mm)
812182428343842
2.25DES-225-08DES-225-12DES-225-18DES-225-24DES-225-28DES-225-34DES-225-38DES-225-42
2.50DES-250-08DES-250-12DES-250-18DES-250-24DES-250-28DES-250-34DES-250-38DES-250-42
2.75DES-275-08DES-275-12DES-275-18DES-275-24DES-275-28DES-275-34DES-275-38DES-275-42
3.00DES-300-08DES-300-12DES-300-18DES-300-24DES-300-28DES-300-34DES-300-38DES-300-42
3.50DES-350-08DES-350-12DES-350-18DES-350-24DES-350-28DES-350-34DES-350-38DES-350-42
4.00DES-400-08DES-400-12DES-400-18DES-400-24DES-400-28DES-400-34DES-400-38DES-400-42

Pre-mounted on a balloon delivery catheter. Order-code format: DES-[diameter]-[length].

Exact dimensional figures, full pressure-compliance charts and order codes are confirmed against the manufacturer's current Instructions for Use (IFU) and catalogue. Request the full datasheet.

Quality & certification

Manufactured under GMP technology by TIBTEXNIKA LLC with internationally certified quality-management systems.

  • ISO 13485:2016
  • ISO 9001:2015
  • Production Licence
  • CE Certificate
Manufacturer
TIBTEXNIKA LLC, Uzbekistan
Category
Coronary Stents
Product family
SINOTECH+
Quality system
GMP · ISO 13485:2016
Regulatory
DRAP — Medical Devices Rules, 2017
Documentation
IFU, datasheet, Free Sale & registration — on request
Intended user
Qualified healthcare professionals only

Product registration certificate

Click a certificate to open it full size.

All devices manufactured by TIBTEXNIKA LLC, Uzbekistan.